Hoshizaki DCM-751BAH(-OS), DCM-751BWH(-OS) E. Electrical Connection, 115-120/60/1, Fig

Models: DCM-751BWH(-OS) DCM-751BAH(-OS)

1 32
Download 32 pages 14.73 Kb
Page 16
Image 16
E. Electrical Connection

E. Electrical Connection

ELECTRICAL CONNECTIONWARNING

1.Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or extensive damage to equipment.

2.This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuses, or damage to existing wiring. This could lead to heat generation or fire.

3.THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could result in death or serious injury.

4.Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the junction box. See

Fig. 3.

Usually an electrical permit and services of a licensed electrician are required.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.

The white lead must be connected to the neutral conductor of the power source.

CAUTION! Miswiring may result in severe damage to the icemaker. See Fig. 3.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

115-120/60/1 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED Failure to properly ground or wire this unit could result in death, serious injury, or severe damage to the icemaker. The white lead must be connected to the neutral conductor of the power source. See diagram below.

115-120/60/1

115-120V

JUNCTION BOX

LBROWN

N WHITE

Fig. 3

16

Page 16
Image 16
Hoshizaki DCM-751BAH(-OS), DCM-751BWH(-OS) instruction manual E. Electrical Connection, 115-120/60/1, Fig