Hoshizaki KM-1400SWH/3-M 7Remove the tie securing the upper units bin control thermostat assembly

Models: KM-1400SWH/3-M

1 24
Download 24 pages 21.57 Kb
Page 12
Image 12
7)Remove the tie securing the upper unit's bin control thermostat assembly.

7)Remove the tie securing the upper unit's bin control thermostat assembly.

8)Remove the bin control thermostat assembly from the shipping hook by lifting it up and shifting it to the right.

9)Remove the thermostat bulb attachment (plastic) of the upper unit from the thermostat extension bracket (stainless).

10)Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of the upper unit.

11)Carefully route the thermostat bulb and capillary tubing of the upper unit through the bottom hole of the upper unit. Remove the bushing from the lower bin control thermostat assembly. Route the bulb and tubing through the hole in the assembly and down into the bin. Reattach the bushing.

12)Secure the lower bin control thermostat assembly in place with the thumbscrews.

13)Carefully insert the thermostat bulb back into the thermostat bulb attachment (plastic).

14)Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat bulb attachment (plastic) of the lower unit with the screws of the upper unit.

15)Insert the plug of the upper unit into the receptacle of the upper unit's bin control thermostat assembly until it locks into place.

16)Replace the panels and baffle in their correct positions.

Thermostat Extension

Bracket (stainless)Thermostat Bulb Attachment Removed from Upper Unit

Thermostat

Capillary

Tubing

Thermostat Bulb

 

Attachment of

 

Lower Unit

Thermostat Bulb

Fig. 6

Fig. 7

12

Page 12
Image 12
Hoshizaki KM-1400SWH/3-M instruction manual 7Remove the tie securing the upper units bin control thermostat assembly