2. Water-Cooled Condenser
a) Connection to an Open Drain System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal copper water tubing is recommended for the condenser water supply line.
•A condenser water supply line
•Condenser drain outlet is 3/8" FPT. A minimum of 3/8" nominal hard pipe is recommended for the condenser drain line.
•In some areas, a back flow preventer may be required in the cooling water circuit.
•In order to maintain the proper high side pressure, the condenser water supply inlet temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation
is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze cycle starts. If the condenser drain outlet temperature is not in the proper range, use a flat blade screwdriver to rotate the adjustment screw on the water‑regulating valve until the temperature is in the proper range (rotate counterclockwise to raise temperature or clockwise to lower temperature).
Icemaker |
|
Water Supply |
|
Inlet |
|
1/2" FPT |
|
Condenser Water |
|
Supply Inlet |
|
1/2" FPT |
|
Condenser |
|
Drain Outlet |
|
3/8" FPT |
|
Icemaker | Bin |
Drain Outlet |
|
3/4" FPT |
|
Condensation |
|
Drain Outlet |
|
3/8" OD Hard Tube |
|
Minimum 3/8" Nominal Hard Pipe
Minimum 3/8" Nominal Copper Water Tubing
Minimum 1/2" Nominal Copper Water Tubing
Icemaker Water Supply Line
Icemaker
| Icemaker Water Supply Line | |
| Drain Valve | |
Vent Tube | Condenser Water Supply Line | |
| ||
| Condenser Water Supply Line | |
| Drain Valve | |
Minimum | Separate piping to approved drain. | |
3/4" Nominal | ||
Leave a | ||
Hard Pipe | ||
gap between the end of each pipe | ||
| ||
Vent Tube | and the drain. | |
|
Bin Drain Outlet
See Manufacturer's Instructions
Floor Drain
Fig. 9 |
|
| Connection to an Open Drain System |
15