14)Place the panels and baffle in position.

7)Remove the thermostat bulb attachment (plastic) of the upper unit from the thermostat extension bracket (stainless).

8)Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of the upper unit.

9)Carefully route the thermostat bulb and capillary tubing of the upper unit through

the bottom hole of the upper unit. Remove the bushing from the lower bin control thermostat assembly. Route the bulb and tubing through the hole in the assembly and down into the bin. Reattach the bushing.

10)Secure the lower bin control thermostat assembly in place with the thumbscrew.

11)Carefully insert the thermostat bulb back into the thermostat bulb attachment (plastic).

12)Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat bulb attachment (plastic) of the lower unit with the screws of the upper unit.

13)Insert the plug of the upper unit into the receptacle of the upper unit's bin control thermostat assembly until it locks in place.

14)Place the panels and baffle in position.

Thermostat Extension Bracket (stainless) or "Z" Bracket (plastic) Depending on Bin

Thermostat Bulb

Attachment of

Lower Unit

Thermostat Bulb Attachment Removed from Upper Unit

Thermostat

Capillary

Tubing

Thermostat Bulb

Fig. 7