F. Electrical Connection
WARNING
1.Electrical connection must be made in accordance with the instructions on a "WARNING" tag, provided with the pig tail leads in the junction box.
2.This icemaker requires a ground that meets the national and local electrical code requirements. To prevent possible electrical shock to individuals or extensive damage to the equipment, install a proper ground wire to the icemaker.
•On single phase models
•On three phase models
•This icemaker must have a separate power supply or receptacle of proper capacity. See the nameplate.
•The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
•When excessive voltage is supplied to the controller board, the icemaker stops running in 3 seconds. See "J. Startup."
•Usually an electrical permit and services of a licensed electrician are required.
KM-1800S_H KM-1800S_H3
Fig. 8a | Fig. 8b |
18