Hoshizaki KM-320MAH, KM-320MWH 2nd Cycle and after with pump drain, Cycle Pump, Fan & Line Valve

Models: KM-320MWH KM-320MAH

1 50
Download 50 pages 28.96 Kb
Page 14
Image 14
2nd Cycle and after with pump drain

2nd Cycle and after with pump drain

IMPORTANT

Freeze cycle time is limited by the freeze timer factory setting even if the float switch does not open.

1.Float switch opens and signals to complete freeze cycle. Drain timer starts counting.

2.Drain timer stops counting. Pump drain is completed.

Drain Pump

Hot Gas Valve

Defrost

Cycle

Freeze

Cycle

Pump, Fan &

Line Valve

Valve

Water

Timer

Defrost

3.Thermistor reads 48°F (9°C). Defrost timer starts counting.

IMPORTANT

Water valve opening is limited to 6 minutes.

5.After the first 5 minutes in freeze cycle. Ready to complete freeze cycle when float switch circuit opens.

4.Defrost timer stops counting. Defrost cycle is completed and freeze cycle starts.

IMPORTANT

Board never accepts freeze completion signal within the first 5 minutes in freeze cycle.

IMPORTANT

1.Board never accepts defrost completion signal within the first 2 minutes in defrost cycle.

2.Defrost cycle time is limited to 20 minutes even if defrost timer does not stop counting.