4. Controls and Adjustments
The dip switch is
Dip Switch No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
|
|
|
|
|
|
|
|
|
|
|
OFF | OFF | OFF | ON | ON | ON | OFF | OFF | OFF | OFF | |
|
|
|
|
|
|
|
|
|
|
|
OFF | OFF | OFF | ON | ON | ON | OFF | OFF | OFF | OFF | |
|
|
|
|
|
|
|
|
|
|
|
Switch Nos. 1 and 2:
Used for adjustment of the defrost timer.
The defrost timer starts counting when the thermistor reads a certain temperature at the evaporator outlet.
Switch Nos. 3 and 4:
Used for adjustment of the drain timer.
When a freeze cycle is completed, the pump motor stops, and the icemaker resumes operation in 2 seconds. Then the pump motor drains the water tank for the time determined by the drain timer. The drain timer also determines the time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
Switch Nos. 5 and 6:
Used for adjustment of the drain counter.
The pump motor drains the water tank at the frequency determined by the drain counter.
Switch Nos. 7 and 8:
Used only for checking the controller board. Usually set in OFF position.
Switch Nos. 9 and 10:
Used for adjustment of freeze timer. The freeze timer determines maximum freeze cycle time. Upon termination of freeze timer, machine initiates the harvest cycle. After 2 consecutive timer terminations, machine will shut down, possibly indicating a problem.