8)If necessary, add any remaining charge to the system through the low-side. Use a throttling valve or liquid dispensing device to add the remaining liquid charge through the low-side access port with the unit running.

9)Close the two refrigerant access valves, and disconnect the hoses and service manifold.

10)Cap the access valves to prevent a possible leak.

B.Brazing

DANGER

1.Refrigerant R-404A itself is not flammable at atmospheric pressure and temperatures up to 176°F (80°C).

2.Refrigerant R-404A itself is not, explosive or poisonous. However, when exposed to high temperatures (open flames), R-404A can be decomposed to form hydrofluoric acid and carbonyl fluoride both of which are hazardous.

3.Always recover the refrigerant and store it in an approved container. Do not discharge the refrigerant into the atmosphere.

4.Do not use silver alloy or copper alloy containing arsenic.

5.Do not use R-404A as a mixture with pressurized air for leak testing. Refrigerant leaks can be detected by charging the unit with a little refrigerant, raising the pressure with nitrogen and using an electronic leak detector.

Note: All brazing-connections inside the evaporator case are clear-paint coated. Sandpaper the brazing connections before unbrazing the components. Use a good abrasive cloth to remove the coating.

C. Removal and Replacement of Compressor

IMPORTANT

Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repair or replacement has been made.

Note: When replacing a compressor with a defective winding, be sure to install the new start capacitor and start relay supplied with the replacement compressor. Due to the ability of the POE oil in the compressor to absorb moisture quickly, the compressor must not be opened more than 15 minutes for replacement or service. Do not mix lubricants of different compressors even if both are charged with R-404A, except when they use the same lubricant.

1)Turn off the power supply.

2)Remove the panels.

3)Recover the refrigerant and store it in an approved container.

42

Page 42
Image 42
Hoshizaki KM-501MRH, KM-501MWH, KM-501MAH service manual Brazing, Removal and Replacement of Compressor

KM-501MAH, KM-501MWH, KM-501MRH specifications

The Hoshizaki KM-501MWH, KM-501MAH, and KM-501MRH are standout models in the commercial ice machine market, known for their robust performance and innovative technologies. These machines are specially designed to meet the diverse needs of restaurants, bars, and other food service establishments that require a reliable source of high-quality ice.

One of the defining features of the KM-501 series is their high production capacity. Each model can produce up to 500 pounds of ice per day, ensuring that even the busiest establishments can keep up with demand. The ice produced is crystal-clear, with a unique crescent shape that not only looks appealing but also melts slowly, making it ideal for drinks and food presentations.

The KM-501MWH model is equipped with advanced technology that ensures energy efficiency and reduced water usage. It features a powerful compressor and a highly efficient evaporator, which work together to minimize energy consumption while maximizing output. This makes it an environmentally friendly choice, reducing operational costs for businesses.

The KM-501MAH model stands out with its air-cooled condenser system, which allows for optimal performance without the need for extensive cooling water lines. This makes the installation process easier and reduces complexity, enabling businesses to set up their ice machine with minimal hassle. Furthermore, it features a self-cleaning mode that simplifies maintenance, contributing to consistent ice quality over time.

On the other hand, the KM-501MRH is designed for rugged environments. It is constructed with high-quality materials that enhance durability and longevity, making it suitable for outdoor applications or establishments located in warmer climates. The stainless-steel design not only contributes to the machine's robustness but also ensures easy cleaning and resistance to rust and corrosion.

Another key characteristic of the Hoshizaki KM-501 models is their user-friendly control panel. These machines come with intuitive controls that allow operators to easily adjust settings and monitor performance. This feature is particularly useful for staff in busy kitchens, enabling them to focus on service without constant checks on ice production.

Overall, the Hoshizaki KM-501MWH, KM-501MAH, and KM-501MRH offer excellent performance, energy efficiency, and user-friendliness. Their combination of innovative technologies, durable design, and high output capacity make them exceptional choices for any establishment in need of reliable ice production. Whether for a bustling restaurant or a bar serving up cocktails, these machines deliver ice that consistently meets high standards.