31
2. KM-501MWH (water-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21 498 226 495 224 465 211
80/27 496 225 491 223 447 203
90/32 495 224 488 221 449 204
lbs./day kg./da
y
100/38 480 218 479 217 413 187
70/21
80/27
90/32
watts 100/38
70/21 567 2.15 627 2.37 863 3.27
80/27 613 2.32 706 2.67 1027 3.89
90/32 627 2.37 771 2.92 1061 4.02
gal./day m3/day 100/38 783 2.96 839 3.18 1328 5.03
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 275 19.3 275 19.3 289 20.3
80/27 275 19.3 275 19.3 296 20.8
90/32 275 19.3 275 19.3 293 20.6
PSIG kg/cm2G100/38 282 19.8 279 19.6 310 21.8
70/21 45 3.2 45 3.2 49 3.4
80/27 45 3.2 45 3.2 51 3.6
90/32 45 3.2 45 3.2 50 3.5
PSIG kg/cm2G100/38 47 3.3 46 3.2 55 3.9
TOTAL HEAT OF REJECTION FROM COMPRESSOR 1,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER 52 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG
26
26
27
2.0
4.0
2.8
3.4
2.6
2.0
3.6
26
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
115-120/60/1 50/10 70/21 90/32
1080
1073
1077
1080
1085
1070
1072
1073
28
29
29
31
1089
1100
1101
1120
27
26
27
27
HARVEST CYCLE TIME
HEAD PRESSURE
3.2
2.8
3.4 2.0
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER 6,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
SUCTION PRESSURE