| SPECIFICATIONS | ||
|
|
|
|
Electrical Rating |
| 115 Volts, 3.6 Amps, 60Hz | |
Watts During |
| 400 (approximately) | |
Watts During Operation |
| 180 (approximately) | |
|
|
|
|
NPS40 Width |
| 22 | 3/8" |
NPS40 Height |
| 30 | 1/2" |
|
|
|
|
NPS40 Depth |
| 26 | 5/8" |
|
|
| |
Weight |
| 210 Pounds | |
|
|
|
|
Exhaust Collar |
| 3" |
|
|
|
|
|
Intake Collar |
| 2" |
|
NPS40 Hopper Cap. |
| 55 Pounds | |
|
|
|
|
NPI40 Hopper Cap. |
| 45 | Pounds |
|
|
| |
EPA |
| Exempt | |
|
|
| |
Burn Rate** |
| 1.0 to 5.0 (Pounds Per Hour) | |
|
|
| |
BTU/h** |
| 8500 to 42500 | |
|
|
| |
Minimum Fireplace Opening Size |
| Front: 22 1/2* W x 20 5/8 H x 14 1/4 D | |
|
| Back: 20 3/8 W |
*In order to install fl ashing fl ush to fi nished wall and centered within the opening the front opening of the fi replace or enclosure must be 32 5/8" wide.
EPA COMPLIANCE
This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test methods by Warnock Hersey.
GENERAL INSTALLATION
PLANNING YOUR INSTALLATION
!WARNING
Read this entire manual before you install and use this heater. failure to follow the instructions may result in
property damage, bodily injury, or even death.
Check with local building offi cials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation.
Before installing we recommend placing the heater outside and load 5 pounds of pellets inside the hopper. Plug the heater in and let it run on HIGH until the pellets run out. This will cure the paint and burn off the oils on the steel, there by mini- mizing any smell inside the home.
HEATER PLACEMENT
Have an authorized dealer install the heater. If you install the heater yourself, have your dealer review your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in this manual.
For
Heater must be positioned so that no combustibles are within, or can swing within (e.g. drapes, doors), 48" of the front of the heater.
If the heater is placed in a location where the ceiling height is less than 7' above the base of the heater, the installation must follow the requirements in the section "Alcove Installations Requirements"