Napoleon Fireplaces NPS40 manual NPI40 INSTALLATION, Minimum Clearances To Combustibles

Models: NPS40 NPI40

1 44
Download 44 pages 1.92 Kb
Page 19
Image 19
NPI40 INSTALLATION

19

NPI40 INSTALLATION

MINIMUM CLEARANCES TO COMBUSTIBLES

Side wall to unit

8"

Maximum mantel depth

10"

Mantel to top of unit

8"

Top facing to unit

6 3/8"

Side facing to unit

6"

Floor protection*

6"*

Figure 18

*Floor Protection: Minimum 6" in front of door and to either side.

MINIMUM MANTEL CLEARANCES

Figure 19

REAR TO TOP VENT CONVERSION INSTRUCTIONS

NOTE: The insert is factory shipped in a rear vent configuration.

1.To vent exit vertically, remove the two screws holding the exhaust cover.

NOTE: Be careful not to damage the gasket.

2.Remove the two screws holding the exhaust tube

NOTE: Be careful not to damage the gasket.

3.Attach the exhaust tube and gasket in the vertical position.

4.Attach the exhaust cover and gasket over the horizontal exit.

Figure 20

Exhaust Cover

MINIMUM CLEARANCES TO COMBUSTIBLES Exhaust Tube

W415-0616 / C / 06.04.08