Napoleon Fireplaces NPI40, NPS40 manual Semi-Annuallyor Every Two Tons Of Pellet, Vacuum Hopper

Models: NPS40 NPI40

1 44
Download 44 pages 1.92 Kb
Page 30
Image 30
SEMI-ANNUALLY (OR EVERY TWO TONS OF PELLET)

30

3.Vacuum out the fi rebox, louvres, air housing, burn pot and the opening at the top of the exhaust manifold of all fl y ash. See Figure 42 and 43.

4.Replace the louvres and burn

pot, latch the viewing door closed and close both side doors.

Exhaust Manifold

Opening

Figure 42

Figure 43

SEMI-ANNUALLY (OR EVERY TWO TONS OF PELLET)

NOTE: More frequent cleaning may be required depending on pellet quality.

!WARNING

Disconnect the power cord prior to conducting service. The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dealer.

NOTE: The heater becomes very hot during operation. Let the heater cool completely and disconnect the power cord prior to conducting service.

VACUUM HOPPER

NPS40:

Run the heater until the pellets run out, then open the hopper and vacuum out the

entire hopper. The dust and any other debris near the bottom should be removed to Figure 44 prevent excessive build-up.

Cleaning the Optional Plated Surfaces

Fingerprints or other marks left on plated surfaces may become etched in place if they are not wiped clean prior to turning the heater on. Wipe the gold with a non-abrasive cleaning solvent and a soft cloth (make sure the heater is cool). Other cleaners may leave a fi lm that may become etched into the fi nish.

SOOT AND FLY ASH FORMATION

The products of combustion will contain small particles of fl y ash. The fl y ash will collect in the exhaust venting system and restrict the fl ow of the fl ue gases. Incomplete combustion occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.

W415-0616 / C / 06.04.08

Page 30
Image 30
Napoleon Fireplaces NPI40, NPS40 manual Semi-Annuallyor Every Two Tons Of Pellet, Vacuum Hopper, Soot And Fly Ash Formation