MINIMUM AIR TERMINAL INSTALLATIONS

14

MINIMUM AIR TERMINAL INSTALLATIONS

C

E

Figure 8

K

 

J

D AFigure 8JBBManual background FManual backgroundI

LG H

E

Illustration dimensions are to the center and the exhaust exit point of the vent.

CLEARANCE

A

24 INCHES

Clearance above grade, veranda porch, deck or balcony.

(Including Vegetation and Mulch)

 

 

 

 

 

B

48 INCHES

Clearance beside or below any windows or doors that open.

 

 

 

 

12 INCHES*

Clearance above any window or door that opens.

 

 

 

C

18 INCHES

Vertical clearance to ventilated soffit located above the terminal within a horizontal

distance of 2 feet from the centerline of the terminal.

 

 

 

 

 

D

0 INCHES

Clearance to an outside corner wall.

 

 

 

E

3 INCHES

Clearance to an inside combustible corner wall or protruding combustible ob-

structions ( vent chase, etc.).

 

 

 

 

 

F

9 INCHES

Clearance to a non-mechanical air supply inlet to the building or a combustion

air inlet to any other appliance.

 

 

 

 

 

G

3 FEET

Clearance to a mechanical air supply inlet.

 

 

 

H

7 FEET**

Clearance above a paved sidewalk or paved driveway located on public property.

 

 

 

I

12INCHES**

Clearance under a veranda, porch, deck or balcony.

 

 

 

 

 

 

J

24 INCHES

Clearance above the roof.

 

 

 

K

2 FEET

Clearance from an adjacent wall including neighbouring buildings.

 

 

 

 

 

 

L

3 FEET within a

Clearance to each side of center line extended above natural gas or porpane

 

height of 15 FEET

meter/regulator assembly or mechanical vent.

 

above the meter/

 

 

regulator assembly

 

 

 

 

*Recommended to prevent condensation on windows and thermal breakage

**This is a recommended distance. For additional requirements check local codes.