Manuals
/
Hoshizaki
/
Kitchen Appliance
/
Cooktop
Hoshizaki
Iii. Technical Information, WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM-900MAF
Models:
KM-900MAF
KM-900MRF3
KM-900MWF
KM-900MRF
1
27
65
65
Download
65 pages
45.09 Kb
24
25
26
27
28
29
30
31
<
>
Specification
Install
Wiring Diagrams
V. Removal And Replacement Of Components
Maintenance
Complete and detailed explanation of the problem
Check a thermistor for resistance by using the following procedures
Defrost Timer
d CONTROLS AND ADJUSTMENTS
Setting
Page 27
Image 27
III.
TECHNICAL INFORMATION
1.
WATER CIRCUIT AND REFRIGERANT CIRCUIT
[a]
KM-900MAF
27
Page 26
Page 28
Page 27
Image 27
Page 26
Page 28
Contents
KM-900MAF KM-900MWF KM-900MRF KM-900MRF3
HOSHIZAKI MODULAR CRESCENT CUBER
MODELS
Attn HOSHIZAKI Technical Support Department
Phone 1-800-233-1940 Technical Service
Complete and detailed explanation of the problem
HOSHIZAKI AMERICA, INC 618 Highway 74 South Peachtree City, GA
CONTENTS
a REFRIGERANT RECOVERY
IV. SERVICE DIAGNOSIS
V. REMOVAL AND REPLACEMENT OF COMPONENTS
SERVICE FOR REFRIGERANT LINES
I. SPECIFICATIONS 1. KM-900MAF
2. KM-900MWF
3. KM-900MRF
4. KM-900MRF3
5. CONDENSING UNIT URC-12F
SPECIFICATIONS MODEL URC-12F
II. GENERAL INFORMATION
1. CONSTRUCTION
a KM-900MAF
b KM-900MWF
c KM-900MRF
d KM-900MRF3
b CONTROLLER BOARD
Features of Control Products “E” Controller Board
2. CONTROLLER BOARD
a SOLID-STATE CONTROL
6 LED Lights and Audible Alarm Safeties
2 Defrost Timer
3 High Temperature Safety - 127 ± 7F
4 Low Water Safety
Freeze Cycle
1 beep every 3 sec. = High Evaporator Temperature 127 F
1 Minute Fill Cycle
Harvest Cycle
Control Products HOS-001A Board
IMPORTANT Water Valve opening is limited to 6 minutes
c SEQUENCE 1st Cycle
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with pump drain
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with no pump drain
d CONTROLS AND ADJUSTMENTS
2 Defrost Timer
Temperature F
Check a thermistor for resistance by using the following procedures
i Disconnect the connector K3 on the board
Dip Switch
3 Drain Timer
The Drain Timer is factory-adjusted, and no adjustment is required
SETTING
e CHECKING THE CONTROLLER BOARD
After the 1 minute water supply cycle, the defrost cycle starts
At this point, the unit should start the defrost cycle
1. WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM-900MAF
III. TECHNICAL INFORMATION
b KM-900MWF
c KM-900MRF and KM-900MRF3
a KM-900MAF
2. WIRING DIAGRAMS
412 ±
Note Pressure Switch
b KM-900MWF
Cut-out
412 ±
Note Pressure Switch
c KM-900MRF
Cut-out
412 ±
Note Pressure Switch
d KM-900MRF3
Cut-out
3. TIMING CHART
If Float Sw. is OFF
From Defrost Cycle To Defrost Cycle
Control
To Freeze Cycle From Freeze Cycle
4. PERFORMANCE DATA a KM-900MAF
b KM-900MWF
c KM-900MRF
b KM-900MRF3
REMEDY
IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION
PROBLEM
POSSIBLE CAUSE
PROBLEM
POSSIBLE CAUSE
REMEDY
PROBLEM
POSSIBLE CAUSE
REMEDY
2. EVAPORATOR IS FROZEN UP
3. LOW ICE PRODUCTION
a See chart 1 - 3, and check dirty Air Filter or Condenser
4. ABNORMAL ICE
5. OTHERS
Solenoid Valve, water system
b EVACUATION AND RECHARGE R-404A
V. REMOVAL AND REPLACEMENT OF COMPONENTS
1. SERVICE FOR REFRIGERANT LINES
a REFRIGERANT RECOVERY
2. BRAZING DANGER
3. REMOVAL AND REPLACEMENT OF COMPRESSOR IMPORTANT
17 Replace the panels in their correct positions
18 Turn on the power supply
5. REMOVAL AND REPLACEMENT OF EXPANSION VALVE
4. REMOVAL AND REPLACEMENT OF DRIER
6. REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVE
6 Install the new valve
1 Turn off the power supply 2 Remove the panels
3 Recover the refrigerant and store it in an approved container
5 Disconnect the Hot Gas Valve or Line Valve using brazing equipment
7. REMOVAL AND REPLACEMENT OF EVAPORATOR IMPORTANT
Page
9. ADJUSTMENT OF WATER REGULATING VALVE - WATER-COOLED MODEL ONLY
Page
Foam Insulation
11. REMOVAL AND REPLACEMENT OF THERMISTOR CAUTION
Thermistor Lead
Cable Tie
Min. 4-3/4 Liquid Bypass Flow
12. REMOVAL AND REPLACEMENT OF FAN MOTOR
14. REMOVAL AND REPLACEMENT OF PUMP MOTOR
13. REMOVAL AND REPLACEMENT OF WATER VALVE
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
1. PREPARING THE ICEMAKER FOR LONG STORAGE
VI. MAINTENANCE AND CLEANING INSTRUCTIONS
2 Move the Control Switch to the “OFF” position
2 Move the Control Switch, on the Control Box, to the “OFF” position
7 Move the Control Switch to the “ICE” position
3 Drain the Potable Water Tank 1 Turn off the power supply
2. CLEANING
CLOSED POSITION
OPEN POSITION
a CLEANING PROCEDURE
b SANITIZING PROCEDURE - Following Cleaning Procedure
3. MAINTENANCE