PROBLEM |
| POSSIBLE CAUSE |
| REMEDY | |||
|
| l) Controller Board | 1. | Defective | 1. | See “II.2[e] CHECKING | |
|
|
|
|
|
| CONTROLLER BOARD.” | |
|
| m) Interlock Switch | 1. | “OFF” position. | 1. | Move to “ON” position. | |
|
| (Cleaning Valve) | 2. | Bad contacts. | 2. | Check for continuity and |
|
|
|
|
|
|
| replace. | |
[2] Water |
| a) Float switch | 1. | Connector disconnected. | 1. | Place in position. | |
continues to |
|
| 2. | Leads opened or defective | 2. | Check and replace. | |
be supplied, |
|
|
| switch. |
|
|
|
and the ice- |
|
| 3. | Float does not move freely. | 3. | Clean or replace. | |
maker will not |
| b) Controller Board | 1. | Defective. | 1. | Replace. | |
start. |
|
|
|
|
|
|
|
[3] Compressor |
| a) Wash Switch | 1. | “WASH” position. | 1. | Move to “ICE” position. | |
will not start |
|
| 2. | Bad contacts. | 2. | Check and replace. |
|
or operates |
| b) High Pressure | 1. | Dirty Air Filter or | 1. | Clean. | |
intermittently. |
| Control |
| Condenser. |
|
|
|
|
|
| 2. Ambient or condenser | 2. Reduce ambient temp. | |||
|
|
|
| water temp. too warm. |
|
|
|
|
|
| 3. Refrigerant overcharged. | 3. | Recharge. | ||
|
|
| 4. Condenser water pressure | 4. | Check and get | ||
|
|
|
| too low or off. [Water- |
| recommended pressure. | |
|
|
|
| cooled model only]. |
|
|
|
|
|
| 5. | Fan not operating. [Except | 5. | See chart 1 - [6]. | |
|
|
|
|
|
|
| |
|
|
| 6. | Refrigerant line or | 6. | Clean and replace Drier. | |
|
|
|
| components plugged. |
|
|
|
|
| c) Water Regulator | 1. | Set too high. | 1. | Adjust lower. | |
|
| d) Overload Protector | 1. | Bad contacts. | 1. | Check for continuity and | |
|
|
|
|
|
| replace. | |
|
|
| 2. | Voltage too low. | 2. | Increase voltage. | |
|
|
| 3. | Refrigerant overcharged or | 3. Recharge. | ||
|
|
|
| undercharged. |
|
|
|
|
|
| 4. | Line Valve continues to | 4. | Check Line Valve's | |
|
|
|
| close in freeze cycle and |
| operation in freeze cycle | |
|
|
|
| Overload Protector |
| and replace. | |
|
|
|
| operates. |
|
|
|
|
| e) Starter | 1. | Bad contacts. | 1. | Check and replace. | |
|
|
| 2. | Coil winding opened. | 2. | Replace. | |
|
| f) Start Capacitor or | 1. | Defective. | 1. | Replace. | |
|
| Run Capacitor |
|
|
|
|
|
|
| g) Magnetic Contactor | 1. | Bad contacts. | 1. | Check for continuity and | |
|
|
|
|
|
| replace. | |
|
|
| 2. | Coil winding opened. | 2. | Replace. | |
|
| h) Compressor | 1. | Wiring to Compressor. | 1. | Check for loose |
|
|
|
|
|
|
| connection or open, and | |
|
|
|
|
|
| replace. | |
|
|
| 2. | Defective. | 2. | Replace. |
|
|
|
| 3. | Protector tripped. | 3. | Reduce temperature. | |
|
| i) Controller board | 1. | Defective. | 1. | See “II.2. [e] CHECKING | |
|
|
|
|
|
| CONTROLLER BOARD.” | |
|
| j) Discharge Temp. | 1. Refrigerant | 1. Recharge. | |||
|
| Switch |
| undercharged. |
|
|
|
|
|
| 2. | Cooling Fan not operating. | 2. See chart 1 - [6] |
| |
|
|
|
|
|
|
|
|
41