Hoshizaki KM-900MWF, KM-900MRF3, KM-900MAF service manual Problem, Possible Cause, Remedy

Models: KM-900MAF KM-900MRF3 KM-900MWF KM-900MRF

1 65
Download 65 pages 45.09 Kb
Page 41
Image 41

PROBLEM

 

POSSIBLE CAUSE

 

REMEDY

 

 

l) Controller Board

1.

Defective

1.

See “II.2[e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

 

 

m) Interlock Switch

1.

“OFF” position.

1.

Move to “ON” position.

 

 

(Cleaning Valve)

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

 

 

replace.

[2] Water

 

a) Float switch

1.

Connector disconnected.

1.

Place in position.

continues to

 

 

2.

Leads opened or defective

2.

Check and replace.

be supplied,

 

 

 

switch.

 

 

 

and the ice-

 

 

3.

Float does not move freely.

3.

Clean or replace.

maker will not

 

b) Controller Board

1.

Defective.

1.

Replace.

start.

 

 

 

 

 

 

 

[3] Compressor

 

a) Wash Switch

1.

“WASH” position.

1.

Move to “ICE” position.

will not start

 

 

2.

Bad contacts.

2.

Check and replace.

 

or operates

 

b) High Pressure

1.

Dirty Air Filter or

1.

Clean.

intermittently.

 

Control

 

Condenser.

 

 

 

 

 

 

2. Ambient or condenser

2. Reduce ambient temp.

 

 

 

 

water temp. too warm.

 

 

 

 

 

 

3. Refrigerant overcharged.

3.

Recharge.

 

 

 

4. Condenser water pressure

4.

Check and get

 

 

 

 

too low or off. [Water-

 

recommended pressure.

 

 

 

 

cooled model only].

 

 

 

 

 

 

5.

Fan not operating. [Except

5.

See chart 1 - [6].

 

 

 

 

water-cooled model].

 

 

 

 

 

 

6.

Refrigerant line or

6.

Clean and replace Drier.

 

 

 

 

components plugged.

 

 

 

 

 

c) Water Regulator

1.

Set too high.

1.

Adjust lower.

 

 

d) Overload Protector

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

2.

Voltage too low.

2.

Increase voltage.

 

 

 

3.

Refrigerant overcharged or

3. Recharge.

 

 

 

 

undercharged.

 

 

 

 

 

 

4.

Line Valve continues to

4.

Check Line Valve's

 

 

 

 

close in freeze cycle and

 

operation in freeze cycle

 

 

 

 

Overload Protector

 

and replace.

 

 

 

 

operates.

 

 

 

 

 

e) Starter

1.

Bad contacts.

1.

Check and replace.

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

f) Start Capacitor or

1.

Defective.

1.

Replace.

 

 

Run Capacitor

 

 

 

 

 

 

 

g) Magnetic Contactor

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

h) Compressor

1.

Wiring to Compressor.

1.

Check for loose

 

 

 

 

 

 

 

connection or open, and

 

 

 

 

 

 

replace.

 

 

 

2.

Defective.

2.

Replace.

 

 

 

 

3.

Protector tripped.

3.

Reduce temperature.

 

 

i) Controller board

1.

Defective.

1.

See “II.2. [e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

 

 

j) Discharge Temp.

1. Refrigerant

1. Recharge.

 

 

Switch

 

undercharged.

 

 

 

 

 

 

2.

Cooling Fan not operating.

2. See chart 1 - [6]

 

 

 

 

 

 

 

 

 

41

Page 41
Image 41
Hoshizaki KM-900MWF, KM-900MRF3, KM-900MAF service manual Problem, Possible Cause, Remedy