PROBLEM | POSSIBLE CAUSE |
| REMEDY | |||||
| l) Controller Board | 1. | Defective. | 1. | See “II.2[e] CHECKING | |||
|
|
|
|
| CONTROLLER BOARD.” | |||
| m) Interlock Switch | 1. | “OFF” position. | 1. | Move to “ON” position. |
| ||
| (Cleaning Valve) | 2. | Bad contacts. | 2. | Check for continuity and |
| ||
|
|
|
|
| replace. | |||
[2] Water | a) Float switch | 1. | Connector disconnected. | 1. | Place in position. | |||
continues to |
| 2. | Leads opened or defective | 2. | Check and replace. | |||
be supplied, |
|
| switch. |
|
|
|
|
|
and the ice- |
| 3. | Float does not move freely. | 3. | Clean or replace. |
| ||
maker will not | b) Controller Board | 1. | Defective. | 1. | Replace. |
| ||
start. |
|
|
|
|
|
|
|
|
[3] Compressor | a) Wash Switch | 1. | “WASH” position. | 1. | Move to “ICE” position. |
| ||
will not start |
| 2. | Bad contacts. | 2. | Check and replace. | |||
or stops | b) High Pressure | 1. Dirty Condenser. | 1. Clean. |
| ||||
operating | Controller |
|
|
|
|
|
|
|
|
| 2. Ambient or condenser | 2. Reduce ambient temp. | |||||
|
|
| water temp. too warm. |
|
|
|
|
|
|
| 3. Refrigerant overcharged. | 3. | Recharge. |
| |||
|
| 4. Condenser water pressure | 4. | Check and get | ||||
|
|
| too low or off. [Water- |
| recommended pressure. | |||
|
|
| cooled model only]. |
|
|
|
|
|
|
| 5. | Fan not operating. [Except | 5. | See chart 1 - [6]. | |||
|
|
|
|
|
|
|
| |
|
| 6. | Refrigerant line or | 6. | Clean and replace Drier. | |||
|
|
| components plugged. |
|
|
|
|
|
| c) Water Regulator | 1. | Set too high. | 1. | Adjust lower. | |||
| d) Overload Protector | 1. | Bad contacts. | 1. | Check for continuity and | |||
|
|
|
|
| replace. | |||
|
| 2. | Voltage too low. | 2. | Increase voltage. | |||
|
| 3. | Refrigerant overcharged or | 3. Recharge. | ||||
|
|
| undercharged. |
|
|
|
|
|
|
| 4. | Line Valve continues to | 4. | Check Line Valve's | |||
|
|
| close in freeze cycle and |
| operation in freeze cycle | |||
|
|
| Overload Protector |
| and replace. | |||
|
|
| operates. |
|
|
|
|
|
| e) Starter | 1. | Bad contacts. | 1. | Check and replace. | |||
|
| 2. | Coil winding opened. | 2. | Replace. | |||
| f) Start Capacitor or | 1. | Defective. | 1. | Replace. | |||
| Run Capacitor |
|
|
|
|
|
|
|
| g) Magnetic Contactor | 1. | Bad contacts. | 1. | Check for continuity and | |||
|
|
|
|
| replace. | |||
|
| 2. | Coil winding opened. | 2. | Replace. | |||
| h) Compressor | 1. | Wiring to Compressor. | 1. | Check for loose |
| ||
|
|
|
|
| connection or open, and | |||
|
|
|
|
| replace. | |||
|
| 2. | Defective. | 2. | Replace. |
| ||
|
| 3. | Protector tripped. | 3. | Reduce temperature. | |||
| i) Controller board | 1. | Defective. | 1. | See “II.2. [e] CHECKING | |||
|
|
|
|
| CONTROLLER BOARD.” | |||
[4] Water | a) Water Solenoid | 1. | Diaphragm does not close. | 1. | Check for water leaks |
| ||
continues to | Valve |
|
|
| with icemaker off. | |||
be supplied in | b) Controller Board | 1. | Defective. | 1. | See “II.2.[e] CHECKING | |||
freeze cycle. |
|
|
|
| CONTROLLER BOARD.” | |||
|
|
|
|
|
|
|
|
|