Hoshizaki KM-2000SRF3, KM2000SWF3 Turn on the power supply to fill the Water Tank with water

Models: KM-2000SWH3 KM-2000SRF3 KM-2000SRH3 KM2000SWF3

1 56
Download 56 pages 4.31 Kb
Page 54
Image 54

19)Turn on the power supply to fill the Water Tank with water.

20)Turn off the power supply after 3 minutes.

21)Remove the Front Panel, and fully open the Cleaning Valve.

22)Move the Control Switch to the “Wash” position.

23)Replace the Front Panel in its correct position.

24)Turn on the power supply to rinse off the cleaning solution.

25)Turn off the power supply after 5 minutes.

26)Remove the Front Panel and Insulation Panel.

27)Drain the Water Tank by removing the Cap located on the front bottom part of the Ice Dropping Hole. See Fig. 3.

28)After the tank has drained, replace the removed parts in their correct positions.

Note: Do not replace the Insulation Panel when you proceed to “[b] SANITIZING PROCEDURE.”

29) Repeat the above steps 16) through 28) three more times to rinse thoroughly.

Note: If you do not sanitize the icemaker, go to step 9) in “[b] SANITIZING PROCEDURE.”

54

Page 54
Image 54
Hoshizaki KM-2000SRF3, KM2000SWF3, KM-2000SRH3, KM-2000SWH3 Turn on the power supply to fill the Water Tank with water