Hoshizaki KMS-1400MLH instruction manual Electrical Connection, Icemaker

Models: KMS-1400MLH

1 29
Download 29 pages 26.79 Kb
Page 18
Image 18

F. Electrical Connection

WARNING

1.Electrical connections must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the condensing unit junction box.

2.Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment.

3.Be sure to install a proper ground to the condensing unit.

4.Power supply and ground wire to the icemaker are supplied from the condensing unit via the wire harness. Connect the icemaker and condensing unit using the wire harness supplied, or fabricate a wire harness using appropriate outdoorrated 18 AWG wire. Use the wiring label or Fig. 8 as a reference when making connections.

Electrical connections must be installed in accordance with applicable national, state, and local regulations.

Usually an electrical permit and services of a licensed electrician are required

The condensing unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size.

Power supply and ground wire to the icemaker are supplied from the condensing unit via the wire harness.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.

On single phase machines, the white lead must be connected to the neutral conductor of the power source. Miswiring results in severe damage to the icemaker. See Fig. 6.

On three phase machines, the transformer's voltage tap switch must be positioned to match incoming voltage at startup. See Fig. 7.

1. Icemaker

Power supply and ground wire to the icemaker are supplied from the condensing unit via the wire harness. Connect the icemaker and condensing unit using the wire harness supplied, or fabricate a wire harness using appropriate outdoorrated 18 AWG wire.

WARNING

To reduce the risk of electric shock, do not connect the power supply until after all wire harness connections have been made.

1)Route the wire harness from the icemaker to the condensing unit.

2)Secure the wire harness to the condensing unit with the strain relief bushing provided (condensing unit accessory).

18

Page 18
Image 18
Hoshizaki KMS-1400MLH instruction manual Electrical Connection, Icemaker