2.Condensing Unit

1)Connect the wire harness wires to the appropriate terminals on the condensing unit's terminal board using the wiring label or Fig. 8 as a reference. Be sure to connect the ground wire (included in the wire harness).

2)Supply power from the electrical panel to the condensing unit. (This differs from KM style installations.)

3)Connect the wire leads in the power supply junction box to the power supplied from the disconnect or electrical panel. Connect a ground wire to the ground screw.

4)Replace all removed parts and panels in their correct positions.

5)Turn on the power supply to the condensing unit.

WARNING

1.Be sure the ground circuit for both units has been properly installed.

2.The condensing unit should have power for a minimum of 4 hours prior to startup to prevent compressor damage.

WARNING

ELECTRICAL CONNECTION

The white lead must be connected to the neutral conductor of the power source.

Miswiring results in severe damage to the icemaker.

(See Fig. below.)

208-230/60/1

Power Supply

Junction Box

(3 wire with neutral for 115V)

 

230V

115- 120V

208-

 

L1

N

Brown

White

L2

Black

Fig. 6

Fig. 7

19

Page 19
Image 19
Hoshizaki KMS-1400MLH instruction manual Electrical Connection