2.Condensing Unit
1)Connect the wire harness wires to the appropriate terminals on the condensing unit's terminal board using the wiring label or Fig. 8 as a reference. Be sure to connect the ground wire (included in the wire harness).
2)Supply power from the electrical panel to the condensing unit. (This differs from KM style installations.)
3)Connect the wire leads in the power supply junction box to the power supplied from the disconnect or electrical panel. Connect a ground wire to the ground screw.
4)Replace all removed parts and panels in their correct positions.
5)Turn on the power supply to the condensing unit.
WARNING
1.Be sure the ground circuit for both units has been properly installed.
2.The condensing unit should have power for a minimum of 4 hours prior to startup to prevent compressor damage.
WARNING
ELECTRICAL CONNECTION
The white lead must be connected to the neutral conductor of the power source.
Miswiring results in severe damage to the icemaker.
(See Fig. below.)
Power Supply | ||
Junction Box | ||
(3 wire with neutral for 115V) | ||
|
230V | 115- 120V |
208- |
|
L1
N
Brown
White
L2
Black
Fig. 6 | Fig. 7 |