Installing the Switch

Installation Procedures

1. Prepare the Installation Site

Cabling Infrastructure - To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10Base-T, 100Base-TX, or 1000Base-T operation.

Be sure to follow the guidelines below to ensure proper operation when installing the switch into a network:

Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45 connectors, maximum length 100 meters (328 ft); Category 3 or better for 10Base-T, Category 5 or better for 100Base-TX, and Category 5, 5e, or 6 for 1000Base-T.

Protection from radio frequency interference emissions.Use electrical surge suppression.Use safe connections with no damaged cables, connectors or shields.

Installation Location - Before installing the switch, plan its location and orientation relative to other devices and equipment. At the front of the switch, leave at least 7.6 cm (3 inches) of space for the twisted-pair cabling. At the back of the switch, leave at least

2.6cm (1 inch) of space for the adapter’s power cord.

2-5