HP 2500CP manual C01. Crrige, C02. Refill, C03. Line Sensor, C04. Service Sttion

Models: 2500CP

1 18
Download 18 pages 4.34 Kb
Page 15
Image 15

C01. C￿rri￿ge

Purpose ( Calibrate the temperature from which the printhead has to be warmed.

THIS CALIBRATION MUST BE DONE WITH THE PRINTHEADS INSTALLED.

If •C0100 OK" ( Calibration done.

If •C01xx ￿￿il" ( Perform Electronics test.

C02. Refill

Purpose ( To ensure the correct position of the carriage assembly in respect to the refill assembly.

When the Carriage Assembly, Refill Assembly or the Electronics Assembly is ordered, a Refill Calibration Tool, a special Carriage height gauge and an Instructions flyer will be included. You must follow the instructions in the flyer in order to correctly calibrate the Refill Assembly and to make sure that the Carriage is at the correct height.

C03. Line Sensor

Purpose ( Calibrate the intensity of the line sensor in the carriage PCA.

Load white media before performing this calibration￿

WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION￿

REPLACE THE LENS COVER BEFORE YOU PERFORM THIS

CALIBRATION IN ORDER TO PREVENT ANY AEROSOL PROBLEMS￿

If •C0300 Done" ( Calibration done.

C04. Service St￿tion

THIS CALIBRATION IS NO LONGER VALID AND SHOULD NEVER BE

PERFORMED￿

C05. Printhe￿ds Alignment

Purpose ( To test and if necessary correct the misalignment between the printheads.

WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION￿

If •C0500 Done" ( Calibration done.

If •C0501 ￿￿il" ( If the calibration pattern is bad, try recovering printheads using the front(panel menu and try the calibration again. If the calibration pattern is bad again, then replace the complete Ink Delivery System of the color that is bad. Perform Electronics Test. Perform Line Sensor Test.

HP DesignJet 2500CP and 2000CP Printers

Quick Reference Service Manual 13

Page 15
Image 15
HP 2500CP manual C01. Crrige, C02. Refill, C03. Line Sensor, C04. Service Sttion, C05. Printheds Alignment