ProCurve Stack Management

Configuring Stack Management

3.Display the Stack Configuration menu by pressing [3] to select Stack Configuration.

Figure 7-6. The Default Stack Configuration Screen

4.Move the cursor to the Stack State field by pressing [E] (for Edit). Then use the Space bar to select the Commander option.

5.Press the downarrow key to display the Commander configuration fields in the Stack Configuration screen.

Figure 7-7. The Default Commander Configuration in the Stack Configuration Screen

6.Enter a unique stack name (up to 15 characters; no spaces) and press the downarrow key.

7-15