HP 275 manual Technical Specifications

Models: 275

1 45
Download 45 pages 61.59 Kb
Page 37
Image 37

QuickSpecs

HP ProLiant BL25p Server Blade

Technical Specifications

HP BladeSystem

Dimensions

Height

10.5 in (26.67 cm)

 

p-Class Server Blade

 

Width

17.60 in (44.70 cm)

 

Enclosure

 

 

 

Depth

28.86 in (73.30 cm)

 

 

 

 

 

Input Specifications

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

 

 

Rated input current

62.5 A at -48 VDC

 

 

 

Rated input Power

3000 W

 

 

Individual Server Blade

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

 

Bay Ratings

Rated input current

6.25 A at -48 VDC

 

 

 

 

 

 

Rated input Power

300 W

 

 

Temperature Range

Operating

50° to 95° F (10° to 35° C)

 

 

Non-Operating

-22° to 140° F (-30° to 60° C)

 

Relative Humidity

Operating

20% to 80%

 

 

(non-condensing)

Non-Operating

5% to 95%

 

 

 

 

 

Wet Bulb Temperature

Operating

82.4° F (28° C)

 

 

 

Non-Operating

101.7° F (38.7° C)

 

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.

HP BladeSystem

Dimensions

Height

10.5 in (26.67 cm)

 

p-Class Server Blade

 

Width

17.60 in (44.70 cm)

 

Enclosure with enhanced

 

 

 

Depth

28.86 in (73.30 cm)

 

backplane components

 

 

Input Specifications

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

 

 

 

Rated input current

125 A at -48 VDC

 

 

 

Rated input Power

6000 W

 

 

Individual Server Blade

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

 

Bay Ratings

Rated input current

14.6 A at -48 VDC

 

 

 

 

 

 

Rated input Power

700 W

 

 

Temperature Range

Operating

50° to 95° F (10° to 35° C)

 

 

Non-Operating

-22° to 140° F (-30° to 60° C)

 

Relative Humidity

Operating

20% to 80%

 

 

(non-condensing)

Non-Operating

5% to 95%

 

 

 

 

 

Wet Bulb Temperature

Operating

82.4° F (28° C)

 

 

 

Non-Operating

101.7° F (38.7° C)

 

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.

DA - 12160 North America — Version 7 — June 27, 2005