6Routine Care, and Disassembly Preparation

This chapter provides general service information for the computer. Adherence to the procedures and precautions described in this chapter is essential for proper service.

CAUTION: When the computer is plugged into an AC power source, voltage is always applied to the system board. You must disconnect the power cord from the power source before opening the computer to prevent system board or component damage.

Electrostatic Discharge Information

A sudden discharge of static electricity from your finger or other conductor can destroy static-sensitive devices or microcircuitry. Often the spark is neither felt nor heard, but damage occurs. An electronic device exposed to electrostatic discharge (ESD) may not appear to be affected at all and can work perfectly throughout a normal cycle. The device may function normally for a while, but it has been degraded in the internal layers, reducing its life expectancy.

Networks built into many integrated circuits provide some protection, but in many cases, the discharge contains enough power to alter device parameters or melt silicon junctions.

Generating Static

The following table shows that:

Different activities generate different amounts of static electricity.

Static electricity increases as humidity decreases.

 

 

Relative Humidity

 

 

 

 

 

Event

55%

40%

10%

 

 

 

 

Walking across carpet

7,500 V

15,000 V

35,000 V

Walking across vinyl floor

3,000 V

5,000 V

12,000 V

Motions of bench worker

400 V

800 V

6,000 V

Removing DIPs* from plastic tube

400 V

700 V

2,000 V

 

 

 

 

42 Chapter 6 Routine Care, and Disassembly Preparation