•The brand, model, and age of the drives
•The amount of unused capacity on the drives
Allow approximately 15 minutes per gigabyte for the rebuild process to complete.
System performance is affected during the rebuild, and the system is unprotected against further drive failure until the rebuild has finished. Therefore, replace drives during periods of low activity, when possible.
When automatic data recovery has finished, the state of the logical volume is updated in
If the
Abnormal termination of a rebuild
If the rebuild process has been terminated abnormally, an event is reported in the system event log and the array remains in interim recovery mode.
Three possible causes exist for abnormal termination of a rebuild:
Posted event | Cause of rebuild termination |
|
|
None of the drives in the array are | One of the drives in the array has |
marked as failed in | experienced an uncorrectable read error. |
|
|
The replacement drive is marked as | The replacement drive has failed. |
failed in |
|
|
|
One of the other drives in the array is | The drive with the illuminated Fault LED has |
marked as failed. | now failed. |
|
|
Each of these situations requires a different remedial action.
One of the drives in the array has experienced an uncorrectable read error.
To resolve this issue:
1.Back up as much data as possible from the logical drive.
CAUTION: Do not remove the drive that has the media error. Doing so causes the logical drive to fail.
2.Restore data from the backup. Writing data to the location of the unreadable sector often eliminates the error.
3.Remove and reinsert the replacement drive. This action restarts the rebuild process.
If the rebuild process still terminates abnormally, do the following:
1.Delete and recreate the logical drive.
2.Restore data from the backup.
The replacement drive has failed.
Verify that the replacement drive has the correct capacity and is a supported model. If these factors are not the cause of the failure, use a different drive as the replacement.
Another drive in the array has failed.
Replacing, moving, or adding hard drives 16