QuickSpecs

HP ProLiant BL30p Server Blade

Technical Specifications

Forwarding Table

Maximum age: 1 to 1,000,000 seconds; default: 300 seconds

Age Time

 

 

Memory

32MB Main, 6MB flash and 16MB packet buffer per interconnect switch

Compliance

IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,

 

802.1p, 802.3ac, 802.3ad (Static), and 802.1Q

 

SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9

 

MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC

 

2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674),

 

Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap

 

(RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch

 

MIBs and Environmental Traps

 

IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC

 

854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC

 

2131) and ZModem,

 

Network Transfer

10 Base-T (half-duplex)

10 Mbps

Rate

10 Base-T (full-duplex)

20 Mbps

 

 

100 Base-TX (half-duplex)

100 Mbps

 

100 Base-TX (full-duplex)

200 Mbps

 

1000 Base-TX (half and

2000 Mbps

 

full-duplex)

 

 

1000 Base-SX (full-duplex) 2000 Mbps

Connector

12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)

 

4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit)

EMI

FCC Class A

 

 

ICES-003 Class A

 

 

AS/NZS 3548 Class A

 

 

VCCI Class A

 

Safety

UL/CUL Listed Accessory

 

 

CE

 

Power Requirements

Temperature R range

Relative Humidity (non-condensing)

Wet Bulb

Temperature

-48VDC: 1050 mA, 50 W maximum (per interconnect switch)

Operating

50° to 95° F (10° to 35° C)

Non-operating

-22° to 140° F (-30° to 60° C)

Operating

20% to 80%

Non-operating

5% to 95%

Operating

82.4° F (28° C)

Non-operating

101.7° F (38.7° C)

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.

Operating and

Dimensions

Performance

 

Specifications for ProLiant

 

BL p-Class GbE2

 

Height

10.405 in (26.43 cm)

Width

1.535 in (3.899 cm)

Depth

27.697 in (70.35 cm)

DA - 11958 Worldwide — Version 19 — August 15, 2005

Page 41

Page 41
Image 41
HP BL30p Server Blades BL30p manual Forwarding Table, Age Time Memory, Compliance, Network Transfer, Rate, Safety