HP BL30p Server Blades BL30p manual Requirements Temperature Range, BladeSystem, Weights

Models: BL30p Server Blades BL30p

1 48
Download 48 pages 62.45 Kb
Page 44
Image 44

QuickSpecs

HP ProLiant BL30p Server Blade

Technical Specifications

EMI

FCC Part 15 Class A

 

 

EN 55022: 1998 (CISPR22)

 

EN 55024: 1998 (CISPR24)

 

CNS 13438 Class A MIC

 

 

CD

 

 

MIC

 

 

AS/NZS 3548 Class A CE

 

 

VCCI Class A

 

Safety

UL to UL 60950, Third Edition

 

C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition

 

TUV/GS to EN 60950:2000

 

CB to IEC 60950 with all country deviations

 

NOM to NOM-019-SCFI

 

 

CE Marking

 

Power

-48VDC: 1050 mA, 125 W maximum (per interconnect switch)

Requirements

 

 

Temperature Range

Operating

50 to 95º F (10 to 35º C)

 

Non-operating

-22 to 140º F (-30 to 60º C)

Relative Humidity

Operating

20% to 85%

(non-condensing)

Non-operating

5% to 95%

 

Wet Bulb

Operating

82.4° F (28° C)

Temperature

Non-operating

101.7° F (38.7° C)

 

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.

Operating and

 

 

Single-Phase Model

3-Phase Model

Performance

Dimensions

Height

5.25 in (13.34 cm)

5.25 in (13.34 cm)

Specifications for 3U HP

 

Width

27.15 in (68.96 cm)

27.15 in (68.96 cm)

BladeSystem

 

 

Depth

17.60 in (44.7 cm)

17.60 in (44.7 cm)

p-Class Power Enclosures

 

 

 

 

 

(North America/Japan)

Weights

No Hot-Plug

47.5 lb (21.55 kg)

47.5 lb (21.55 kg)

 

 

Power Supplies

 

 

 

 

All Hot-Plug

99.5 lb (45.13 kg)

125.5 lb (56.93 kg)

 

 

Power Supplies

 

 

 

Input Requirements

Rated input voltage

200 VAC to 240 VAC

200 VAC to 240 VAC

 

 

 

 

line to line

 

 

Rated input frequency

50 Hz to 60 Hz

50 Hz to 60 Hz

 

 

Rated input current

24A

24A per phase

 

 

per side

 

 

 

 

Rated input power

5760 W

9976 W

 

 

per side

 

 

 

 

Power cord

1 NEMA L6-30P per

1 NEMA L15-30 per

 

 

 

side

side

DA - 11958 Worldwide — Version 19 — August 15, 2005

Page 44

Page 44
Image 44
HP BL30p Server Blades BL30p Requirements Temperature Range, Operating Single-Phase Model Performance Dimensions, Weights