A Emulex CNA specifications

This chapter contains the following CNA specifications:

“Environmental specifications” (page 22)

“Physical specifications” (page 22)

“Emulex CNA media specifications” (page 23)

Environmental specifications

Table 3 (page 22) lists the CNA environmental specifications.

Table 3 Environmental specifications

Environment

Minimum

Maximum

Operating temperature

0°C (32°F)

55°C (131°F)

Storage temperature

–40°C (–40°F)

70°C (158°F)

Relative humidity (non-condensing)

5%

85%

Airflow

150 lf/min (minimum)

N/A

Physical specifications

Table 4 (page 22) lists the physical specifications.

Table 4 Physical specifications

Parameter

Range

PICe slot requirements

Minimum eight-lane PCI Express slot

Physical dimension

Low-profile form factor, 6.60 inches by 2.71 inches, and accommodates both the

 

full-height and low-profile bracket

Power requirements

14.5 Watts typical

Agency approvals

Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1

 

UL recognized to UL60950-1 2nd Edition

 

CUR recognized to CSA 22.2, No. 60950-1-07

 

TUV certified by to EN60950-1

 

FCC Rules, Part 15, Class A

 

Industry Canada, ICES-003, Class A

 

EMC Directives 2004/108/EEC (CE Mark)

 

EN55022, Class A

 

EN55024

 

Australian EMC Framework (C-Tick Mark)

 

AS/NZS CISPR22:2006 Class A

 

Japan VCCI, Class A

 

Taiwan BSMI, Class A

 

Korea KCC, Class A

 

RoHS Compliant (Directive 2002/95/EC)

 

China RoHS compliant

22 Emulex CNA specifications

Page 22
Image 22
HP CN1100E, CN1000E manual Emulex CNA specifications, Environmental specifications, Physical specifications