24 HP ProLiant Cluster F100 Installation Guide

IMPORTANT: Using a public network as the dedicated interconnect path is not recommended because it represents a potential single point of failure for cluster communication.

Redundant Interconnect

MSCS enables you to configure any supported network card as a possible path for intracluster communication. If you are employing a dedicated interconnect, use MSCS to configure the LAN network cards to serve as a backup for the interconnect.

Multiple Cluster Setup

For a multiple cluster setup, be sure that:

Each two-node cluster is using the same model of ProLiant server.

The storage system has the latest supported firmware version.

The same HBAs are being used.

NOTE: The MSA1000 storage system can be upgraded using the MSAFlash utility. To learn more about MSAFlash and how to use it, refer to the documentation provided within the download of the MSA1000 firmware upgrade package.

Installing the Software

The following sections describe the software installation steps for the:

F100 for MSA1000 with Microsoft® Windows® Server 2003, Enterprise Edition

F100 for MSA1000 with Microsoft® Windows® 2000 Advanced Server

F100 for the RA4100 with Microsoft® Windows® Server 2003, Enterprise Edition

F100 for the RA4100 with Microsoft® Windows® 2000 Advanced Server

Proceed with these steps after you have all equipment installed and the switches or hubs, storage system, and one server powered up.