Technical Specifications

 

 

Factory Preset Display Modes (Continued)

 

 

 

 

Preset

Pixel Format

Horz Freq (kHz)

Vert Freq (Hz)

 

 

 

 

13

1152 x 900

71.7

76.1

 

 

 

 

14

1280 x 1024

64.0

60.0

 

 

 

 

15

1280 x 1024

80.0

75.0

* Modes 12, 13, 14, and 15 apply to 1706 and 1906 models only

Entering User Modes

The video controller signal may occasionally call for a mode that is not preset if:

You are not using a standard graphics adapter.

You are not using a preset mode.

If this occurs, you may need to readjust the parameters of the monitor screen by using the on-screen display. Your changes can be made to any or all of these modes and saved in memory. The monitor automatically stores the new setting, then recognizes the new mode just as it does a preset mode. In addition to the 15 factory preset modes, there are four user modes that can be entered and stored.

Energy Saver Feature

When the monitor is in its normal operating mode, the monitor uses less than 40 watts of power and the Power light is green.

The monitor also supports a reduced power state. The reduced power state will be entered into if the monitor detects the absence of either the horizontal sync signal and/or the vertical sync signal. Upon detecting the absence of these signals, the monitor screen is

User Guide

B–7

Page 51
Image 51
HP 1706, FP 1906 manual Energy Saver Feature, Entering User Modes