Platform-Specific Issues

Platform-Specific Issues

HP HP-UX

Failure to Mount File System after Failover or Failback

If you are unable to mount a previously configured file system after a failover or failback, run File System Check on the logical volume and retry the mount.

Example: FSCK -O full /dev/vg0#/lvol#

Configuring Host Server Remote Copy Sets

Remote copy sets (RCSs) at the target site will acquire the world wide name of their RCSs at the initiator site when a failover occurs. HP recommends that you not configure the RCS on the HP-UX host servers at the target site until after a failover.

HP OpenVMS

Additional Software Requirements

Remedial kits that you may require are available at:

ftp://ftp.itrc.hp.com/openvms_patches/alpha

HP Tru64 UNIX

Prevent Possible Data Corruption

If during the failover procedure you are unable to stop all applications and dismount all units that are part of a remote copy set, you must reboot hosts prior to failback. Doing this prevents possible data corruption caused by writing stale data from host cache to the units after failback.

Note: Extreme care must be used when creating and managing remote copy sets on an ATM link. If these links are overstressed (for example, an excessive number of remote copy sets created for a given environment), unexpected behavior may result, such as loss of remote copy sets and link failures.

Accessing Special Device Files During Fabric Failover

HP recommends that no attempt be made to access the special device files during a fabric failover. Running any commands against the block or raw devices in /dev/disk or /dev/rdisk is highly discouraged. In rare instances, running the FILE command against raw or block devices during a fabric failover has prevented the surviving path from coming online following failure of the original path.

12

Data Replication Manager HSG80 ACS Version 8.7P Release Notes