label=HP
#Corresponds to kernel 
3.Reboot the server.
HP System Management Homepage Session Time-out  Error
The default value of the 
NOTE: The maximum value for 
| From the command line: | 1. | Set  | 
| 
 | 
 | # /opt/hp/hpsmh/sbin/smhconfig | 
| 
 | 
 | 
 | 
| 
 | 2. | Restart HP SMH: | 
| 
 | 
 | # /etc/init.d/hpsmhd restart | 
| From HP SMH : | 1. | Sign in to HP SMH. | 
| 
 | 2. | Select Settings→SMH→Security→Timeouts. | 
| 
 | 3. | Modify the UI timeout (seconds) value, and then click | 
| 
 | 
 | Apply. | 
| 
 | 4. | Sign out of HP SMH. | 
| 
 | 5. | Restart HP SMH: | 
# /etc/init.d/hpsmhd restart
HP SAS Integrated Raid (IR) Configuration Utility May Cause Kernel Panics on RHEL4U7
The Integrated Raid (IR) Configuration Utility, cfggen, is a Linux command line utility that configures the IR functionality of the HP Serial Attached SCSI (SAS) controllers that are used in 
This issue has been fixed by MPT driver, 3.12.14.00. If you want to use cfggen on RHEL4U7, first install the proper MPT driver. You can also use the EFI executable utility,cfggen.efi, to create volumes.
For information about using the cfggen.efi utility, see the SmartSetup Scripting Toolkit Deployment Guide:
Flashing HP PCIe 2-port  1000Base-T  adapter (AD337A) Adapters
The HP PCIe 
60 Known Issues