ADC Calibration

ADC - YPbPr Calibration

1.Input “SMPTE”Test patter (Figure 1) from generator to TV component port. (component 1 or 2 is ok)

2.TV set to Factory Menu. Use cursor on the remote to move to “ADC Calibration” setting. Like Figure 2.

3.Press “OK” on the remote.

ADC - VGA Calibration

1.Input 16 gray scale pattern (Figure 1) from generator to TV VGA port.

2.TV set to Factory Menu. Use cursor on the remote to move to “ADC Calibration” setting. Like Figure 2.

3.Press “OK” on the remote controller.