Removal and Replacement Procedures

To remove the component:

1. Be sure that the online and activity LEDs on the failed drive are both off.

CAUTION: To prevent improper cooling and thermal damage, do not operate the system unless all bays are populated with either a component or a blank.

2. Remove the failed drive.

3

2

1

To replace a hot-plug SCSI hard drive:

1.Slide the drive into the bay until it locks into place.

2.Close the lever.

CAUTION: Data loss can occur if the drive is not firmly seated.

3.Be sure that the drive LEDs illuminate one at a time and then turn off together to indicate that the system has recognized the new drive.

In fault-tolerant configurations, allow the replacement drive to be reconstructed automatically with data from the other drives. While reconstruction is in progress, the online LED flashes.

2-6

HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide