Specifications
Hot-Plug AC Power Supply
Table
Specification | Value |
Height | 12.7 cm (4.5 in) |
|
|
Width | 15.9 cm (6.25 in) |
|
|
Depth | 24.1 cm (9.5 in) |
|
|
Weight | 2.9 kg (6.4 lb) |
|
|
Note: The MSA500 system power supply specifications are calculated without the blower.
Hot-Plug DC Power Supply
Table
Specification | Value |
Voltage |
|
|
|
Nominal input voltage | |
|
|
Maximum input voltage | 75 VDC |
|
|
Operating voltage range | 36 to 72 VDC |
|
|
Ripple/Noise | 100 mV PARD* |
|
|
Overshoot | Must remain within regulation limits during startup or shutdown |
|
|
Current |
|
|
|
Max steady state input current | 13.2 A |
|
|
70 A | |
|
|
Input | Customer must provide fusing for facility DC feeds that protect the |
| system from catastrophic |
| sustain all |
|
|
Max input current slew rate | 1A/uS |
|
|
Max rated power | 499 W |
|
|
*Periodic and random noise (PARD). Maximum allowable