Removal and Replacement Procedures
HP StorageWorks Modular Smart Array 500 Controller
When the MSA500 controller in a
CAUTION: Failure to migrate the cache to a new controller and flush the data can result in loss of the data that is written in the cache but was unable to be written to the hard drives before controller failure.
To remove the component:
2
1
To restore the data:
1.Remove the cache modules from the failed controller. Refer to
2.Install the cache modules in the new controller.
3.Install the new controller and allow the cache to write the stored data.
To replace the controller:
1.Slide the controller into the bay until it locks into place.
2.Close the lever.
3.Verify that the controller is seated properly by observing the controller LEDs. When seated properly, the LEDs illuminate when the system is powered.
HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide |