Table 1 <controller> strings

<controller>

Meaning

<seg:bus:dev:func>

A controller having the PCI segment id, bus id, device id

 

and function id is addressed

all

Addresses all controllers in the system

<model>

Controllers of a particular type indicated by the <model>

 

string are addressed

SET_MODE

IMPORTANT: If you are using HBA mode, do not install any disk that has previously been a part of a RAID volume into the system.

Use set_mode to change the mode of the controller. If the controller is already in the required mode the following message appears:

The controller at <seg:bus:dev:func> is already in HBARAID mode

Syntax

saupdate set_mode <controller> <hbaraid> [-f]

<controller> can be any one of the strings listed in Table 1 (page 20).

An alert message about the possible data loss is displayed when a mode change command is issued. A confirmation is required before the actual mode change is made. This ensures that an unintentional change of mode does not happen.

The –findicates the user is aware of the changes that are being made, and no warning message or confirmation regarding the mode change is needed.

20 Installing, verifying, and configuring the controller

Page 20
Image 20
HP Smart Array (RAID) Host Bus Adapters manual Setmode