Interpreting Hardware Paths
Examples
Example 2-1 Hardware Path for a Direct Fabric Attach Device
Adapter Domain Area Port Bus Target LUN
0/1/2/0.1.19.255.0.0.0
Example 2-2 Hardware Path for a Private Loop Device
Adapter Domain Area Port Bus Target LUN
0/1/2/0.8.0.255.0.1.0
Table 2-3 describes each field in the hardware path.
Table 2-3 Hardware Path Field Descriptions
Field | Value | Fibre Channel Topology of HBA |
| |
Fabric Topologies | Private Loop | |||
|
| |||
Adapter | The hardware path of the Fibre Channel adapter through which the Logical Unit Number (LUN) is seen. | |||
| For multiport adapters, this field describes a specific port on the adapter. | |||
Domain | Dependent on the Fibre | Typically the Domain ID of the switch to | 8: | |
| Channel topology of the | which the target device is attached, taken | indicate private loops. Fibre Channel | |
| HBA. | from the most significant byte of the | switches seen by | |
|
| N_Port ID of the target device. | be configured with domain ID of 8. |
Area | Depends on the Fibre |
| Channel topology of the |
| HBA. |
Taken from the second byte of the N_Port 0 ID of the target device. On some switches, the second byte of the N_Port ID encodes the switch port to which the device is connected. The encoding method depends on the switch. See your switch manual to interpret this field.
Port | Depends on the Fibre |
| Channel topology of the |
| HBA and the target |
| device, and on the LUN |
| addressing method |
| used. |
For LUNs with Peripheral Device Addressing, the value of this field is always
255.
For other LUN methods, the value of this | For other LUN methods, the value of |
field is the least significant byte of the | this field is the Loop ID of the target |
N_Port ID of the target device. | device. |
Bus | Depends on the Fibre |
| Channel topology of the |
| HBA and the target |
| device, and on the LUN |
| addressing method |
| used. |
For LUNs with Peripheral Device | For LUNs with Peripheral Device |
Addressing, the value of this field is the | Addressing, the value of this field is |
upper 4 bits of the least significant byte | the upper |
of the N_Port ID of the target device. | target device. |
For LUNs with Logical Unit Addressing, the value is the Bus Number field of the LUN. For LUNs with Volume Set Addressing (Flat Space Addressing), the value is bits 7 - 13 of the LUN.
18 Fibre Channel Adapter Installation