Chapter 4

Peripherals and Accessories

Array Logs

The array logs consist of the following controller logs:

Events

Errors

Unexpected conditions

Configuration changes

Environmental changes

Fibre Channel Port Statistics

Historical Fibre Channel port information

Performance

Input/Output per second

Flash

Event log stored in flash memory in the event of a loss of battery power

The array logs are stored in two (2) locations: The Controller(s).

Host operating system: The HP Command View SDM software polls the array controller every 15 minutes and updates a host OS directory located on the host server internal disk drive. These logs contain “Event” data will be commonly accessed by the support entity HP Response Center.

Note: The Fibre Channel Port Statistics and Performance log are stored in dynamic memory and will be lost when the array is powered off.

Supported Operating Systems

For Additional Information please see the Disk Storage Information located on the SPOCK web site: (http://hpso.rose.hp.com/spock/index.shtml#Disk_Storage_Information)

HP-UX

Windows NT

Windows 2000

Windows .NET (when available, VA7110 only)

Linux

Solaris—Requires management station

AIX—Requires management station

NetWare—Requires management station

MPE/iX—Requires management station; requires HP SCSI-FC router (A5814A option 003) for Fibre Channel connectivity prior to MPE/iX 7.5; connectivity also supported via Native Fibre Channel in MPE/iX 7.5 or greater.

For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):

Spock Website:

For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm

For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm

For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm

Partnership Website:

http://partner.americas.hp.com/

HP e3000 Business Servers Configuration Guide – Effective 1/04

4-117

Information Subject to Change