71
Depth Offset

(Advanced)

Depth Offsetwill adjust the digital depth readout to indicate depth from the waterline or boats
keel. Enter a positive vertical measurement from the transducer to the waterline to read the depth
from the waterline. Enter a negative vertical measurement from the transducer to keel to read the
depth from the keel. This menu choice is available only when in Advanced User Mode (see Setup
Menu Tab: User Mode.)
To change the Depth Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Depth Offset on the Setup
menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset setting.
(-10.0 to +10.0 feet or -3 to 3 meters [International Models Only], Default = 0)
Temp Offset

(Advanced)

Temp Offset will adjust the temperature readout by the amount entered. This menu choice is
available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
To change the Temp Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Temp Offset on the Setup
menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset setting.
(-10.0 to +10.0 degrees, Default = 0)
Speed Calibration

(Advanced, with Temp/Speed Only)

Speed Calibrationwill adjust the speed readout by the percentage entered, and will appear in the
menu if a Temp/Speed Accessory is connected and the paddlewheel has moved at least once,
when the unit is in Advanced User Mode (see Setup Menu Tab: User Mode.)
To change the Speed Calibration setting:
1. Make sure you are in Advanced User Mode, then highlight Speed Calibration on the
Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Speed Calibration
setting. (-20% to +20%, Default = 0%)
70
Select Readouts

(Advanced, Sonar View Only)

Select Readoutssets individual digital readouts on the Sonar View.
This Advanced feature allows you to select what data will be
displayed in each of 5 fixed-position data windows arranged around
the left and bottom edges of the Sonar View screen, or whether a
particular window will be turned off, displaying nothing in that area;
you can access this menu choice only when in Advanced User Mode
(see Setup Menu Tab: User Mode.)
Data windowscan display readouts from supported accessories such
as Temp/Speed. Each data window can either be empty or contain
one of the following:
• Heading • Temperature
• Navigation • Time + Date
• Position • Triplog
• Speed • Voltage.
To Select Readouts:
1. Make sure you are in Advanced User Mode, then highlight Select Readouts on the Setup
main menu.
2. Use the RIGHT 4-WAY Cursor Control key to initiate this procedure.
3. The Select Readouts submenu will appear, showing a list of all Readouts. Use the UP or
DOWN Cursor keys to select a particular Readout position, then use the RIGHTor LEFT
Cursor keys to change what will be displayed at that position. (Heading, Navigation,
Position, Off, Speed, Temperature, Time+Date, Triplog, Voltage)
Default Sonar View Customized Sonar View
Select Readouts
M87_Man_531352-1_A.qxd 12/9/2004 3:28 PM Page 76