1.Screw 2" coupling onto threaded end of 2" standard pipe.

2.Slide cast iron pedestal base up over the unthreaded end of 2" standard pipe.

3.Screw 1" suction pipe into install-a-socket. Suction pipe should be long enough to allow 3" clearance from bottom of tank. Apply gasoline-resistant pipe compound to male threads.

4.Insert 1" suction pipe into 2" pipe and screw install-a-socket into coupling on end of 2" pipe.

5.Assemble union onto lower end of 1" suction pipe conforming to your site's piping layout. Note that the GASBOY base is provided with an opening on one side, so that an elbow can be used and the suction brought out horizontally aboveground if desired, instead of straight down through the island.

6.Slide base down to proper position at the lower end of the pedestal, tighten six set screws.

7.Screw the 2" male thread on the base of the pump into the upper end of the install-a-socket. Apply gasoline pipe compound to all male threads.

8.Securely mount pedestal base to concrete. If the pump is not securely fastened to the foundation, supply line leaks at unions and pipe joints may occur.

See the Conduit section for correct installation of electrical conduit. All underground piping and swing joints are supplied by the customer. All metallic piping should be at least Schedule 40 wrapped/coated black steel pipe with extra-heavy malleable iron screw type fittings. Protect metallic piping in contact with the ground with a properly designed cathodic protection system.