Husky 1800 Series, 70 Series manual Installation, Direct Mount on Underground Tanks

Models: 1800 Series 70 Series

1 51
Download 51 pages 32.89 Kb
Page 11
Image 11
Direct Mount on Underground Tanks

Installation

Direct Mount on Underground Tanks

1.Screw 2" coupling onto 2" standard pipe.

2.Screw 2" standard pipe into 2" tank flange. Apply compound to threads at bottom of base to prevent surface water from entering the tank.

3.Screw 1" suction pipe into install-a-socket. Suction pipe should be long enough to allow 3" clearance from bottom of tank. Apply gasoline-resistant pipe compound to male threads.

4.Lower 1" suction pipe through 2" standard pipe into tank. Tighten install-a-socket into coupling at top of standard pipe.

5.Screw pump (2" threaded base) into install-a-socket. This is a suction line connection and must be tight. Apply gasoline-resistant pipe compound to male threads.

See the Conduit section for correct installation of electrical conduit.

9312