Husqvarna 230 ACX/220 AC manual Menu Functions, The Test IN 3-2-4 function is used to test how

Models: 230 ACX/220 AC

1 82
Download 82 pages 35.15 Kb
Page 55
Image 55
The Test IN (3-2-4)function is used to test how

6. MENU FUNCTIONS

• Test IN (3-2-4)

The Test IN (3-2-4)function is used to test how

Follow loop out

Automower finds its way into the charging

 

station.

 

 

Follow loop in

 

Corridor width

 

Test IN

 

Test OUT

 

3-2-4

When the function is selected the mower will

 

immediately follow the boundary wire, guide 1 or

 

guide 2, depending on which one it finds first, in

 

to the charging station. If there is a passage and

 

the mower can not run through it, the Corridor

 

width value is set too high. When Test IN is

 

activated, the mower runs at the greatest

 

distance from the wire that the selected corridor

 

width permits.

 

The adjacent picture shows how Automower

 

negotiates a passage when a value of 5 is set for

 

the Corridor width, but not when a value of 6 is

 

set.

 

 

3012-672

IMPORTANT INFORMATION

When Test IN (3-2-4)is used, the house icon on the display will come on and the mower will remain in the charging station. Press the Home button to return to operations.

Test OUT (3-2-5)

The Test OUT (3-2-5)function is used to try different charge exit settings and to find out how far it is from the charging station to a remote area.

To test the settings for Follow loop out (3-2-1):

State the value 100 % for Proportion for the remote area to be tested. Place Automower in the charging station and select Test OUT (3-2-5). The mower will now leave the charging station directly according to the stated direction and start mowing after the stated distance. Reset the Proportion value when testing is finished.

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT

3-2-4

56 - English

Page 55
Image 55
Husqvarna 230 ACX/220 AC manual Menu Functions, The Test IN 3-2-4 function is used to test how, Important Information