Husqvarna 230 ACX/220 AC manual IMPORTANT INFORMATION The low voltage cable must not be extended

Models: 230 ACX/220 AC

1 82
Download 82 pages 35.15 Kb
Page 19
Image 19
IMPORTANT INFORMATION

3. INSTALLATION

The charging station must be positioned with a great deal of free area in front of it (at least 10 ft). It should also be positioned centrally in the working area so that Automower can easily find the charging station and quickly reach all parts of the working area.

It is a good idea to place the charging station in the shadow. The battery is spared if it is charged in the lowest possible ambient temperature.

The charging station must be positioned on relatively level ground. The height difference must not differ more than 2" between the front and rear of the charging station.

The charging station must not be positioned so that its plate bends.

Consider the distance to a wall socket when choosing the position. The charging station should be connected to a 120V wall socket via the low voltage cable and transformer.

The supplied low voltage cable is 66 ft long.

Tip! It is possible to let the low voltage cable cross the working area. It must then be either stapled down or buried. In some cases there is a better positioning option for the charging station than close to a house wall or by the closest wall socket.

IMPORTANT INFORMATION

The low voltage cable must not be extended.

IMPORTANT INFORMATION

The transformer is for indoor use only.

The transformer must be placed where it is well ventilated and is not exposed to direct sunlight.

It is recommended to use an earth fault-breaker when connecting the transformer to the wall socket.