7. GARDEN EXAMPLE

Proposals for installation and settings

Area: 0.12 acre. There are several islands. No guide wire is necessary. The mower’s default settings do not need to be changed.

Timer: Operating time of 7 hours per day.

Exit angles: One sector 90°- 270°.

Search method: Irregular.

Delay: Guide 1 7 minutes, Guide 2 7 minutes and boundary wire 11 minutes.

Corridor width: 6.

Area: 0.25 acre. There is one small island. Guide wire recommended through the passage.

Timer: Operating time of 14 hours per day.

Exit angles: One sector 70°-190°.

Follow loop out: Direction Guide 1, Distance 20 m (65 ft) and Proportion 25 %.

Search method: Irregular, Follow guide wire in and Follow boundary wire in.

Delay: Guide 1 7 minutes, Guide 2 7 minutes and boundary wire 11 minutes.

Corridor width: Guide 1 6, boundary wire 20.

This example only applies to 230 ACX.

Area: 0.5 acre. Two guide wires are recommended.

Timer: Operating time of 19 hours per day.

Exit angles: One sector 90°-270°.

Follow loop out: Area 1; Direction Guide 1, Distance 30 m (98 ft) and Proportion 15 %. Area 2; Direction Guide 2, Distance 30 m (98 ft) and Proportion 30 %.

Search method: Irregular, Follow guide wire in and Follow boundary wire in.

Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 11 minutes.

Corridor width: Guide 1 4, Guide 2 4 and boundary wire 6.

3012-527US

3012-528US

3012-743US

English - 67