Husqvarna 230 ACX/220 AC Laying the boundary wire in towards the charging station, Installation

Models: 230 ACX/220 AC

1 82
Download 82 pages 35.15 Kb
Page 29
Image 29
Laying the boundary wire in towards the charging station

3. INSTALLATION

The boundary wire must not be crossed on the path to and from an island.

Laying the boundary wire in towards the charging station

The boundary wire can be routed in several different ways in towards the charging station. The best alternative is to route the wire completely outside the charging station, see alternative 1. The wire can also be placed under the charging station plate as shown in alternative 2 in the illustration. However, the wire should not be placed outside alternative 2 because it can then be difficult for Automower to find the charging station.

When connecting to the charging station, the right end of the boundary wire should be guided into the right-hand hole and the cable's left end in the left-hand hole.

Joining the boundary wire

If the boundary wire is not long enough and needs to be spliced: Use original solderless coupler. It is waterproof and gives a reliable electrical connection.

To splice: Insert both cable ends in the coupler. Now press down the button on top of the connector fully. Use a pair of pliers or the like, as the button on the connector is difficult to press down by hand.

IMPORTANT INFORMATION

Twisted cables, or a screw terminal (chock-block), insulated with insulation tape is not a satisfactory splice. Soil moisture will cause the conductors to oxidize and after a while result in a broken circuit.

3012-686US

1.

2.

3012-671

3012-462

3012-535

3012-536

30 - English

Page 29
Image 29
Husqvarna 230 ACX/220 AC Laying the boundary wire in towards the charging station, Joining the boundary wire, Installation