Husqvarna MZ5225BF / 968999720 Starting the engine with a weak battery, To attach jumper cables

Models: MZ6125, MZ7227, MZ5225BF, MZ6125BF, MZ5225C, MZ6125C, MZ25, MZ5225 MZ5225 / 968999717 MZ25 / 968999780 MZ5225C / 968999748 MZ6125 / 968999718 MZ5225BF / 968999720 MZ7227 / 968999719 MZ6125BF / 968999721 MZ6125C / 968999749

1 77
Download 77 pages 13.21 Kb
Page 30
Image 30
Starting the engine with a weak battery

operation

Starting the engine with a weak battery

WARNING!

Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials To attach jumper cables away from batteries. Always wear eye protection when around batteries.

IMPORTANT INFORMATION

Your mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12-volt negative grounded system. Do not use your mower to start other vehicles.

If your battery is too weak to start the engine, it should be recharged. (See “Battery” in the Maintenance Section.)

If “jumper cables” are used for emergency starting, follow this procedure:

To attach jumper cables

8011-642

Jumper cable connection

Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis.

Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery.

Connect the other end of the BLACK cable to a good CHASSIS GROUND on the mower with the discharged battery, away from the fuel tank and battery.

To remove cables, reverse order

Remove BLACK cable first from chassis and then from the fully charged battery.

Remove RED cable last from both batteries.

English-30

Page 30
Image 30
Husqvarna MZ5225BF / 968999720 manual Starting the engine with a weak battery, To attach jumper cables, operation