SERVICING VERTICAL LIGHTING
Refer to door manufacturer’s manual for servic-
ing of vertical lamps.
SERVICING DOORS AND FRAMES
See door manufacturer’s service manual for
servicing information. One manual is shipped
with each merchandiser.
REPLACING DOOR OR DOOR FRAME PARTS
Parts for Reach-in doors and door frame
assemblies must be ordered direct from the door
manufacturer This includes the glass doors, door
frame assemblies, lamps, ballasts, door handles,
hold open slides, and power cords.
Refer to specific warranty supplied with the
door. The manufacturers have a warranty
against moisture penetration, a warranty against
tempered glass breakage, and a warranty on
ballasts. Lamps are not covered by Hussmann
or the door manufacturer.
REPLACING DAMAGED DRAIN FITTING
The following procedure is for the field repair of
a broken drain fitting.
1. Use a drill with a 17/8-inch (48 mm) hole saw
to drill out the bottom of the drain fitting. Be sure
to drill completely through fitting and bottom
liner.
2. Apply teflon tape to threaded end of adapter
and screw into threaded end of tee.
3. Apply an ABS and PVC compatible primer
and sealer to adapter and inside of drain. Insert
adapter into drain fitting.
Reach-In
P/N 0387183_D 6-9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Drain Fitting Viewed from Inside Case
End Section View
Foam Bottom
Assembly
Modified
Drain Fitting
PVC Adapter
11/2 x 11/4 in.
(38 x 32 mm)
(obtained at local
building supply store)
Tee
11/4in.TxSxS
(32 mm)