DOOR ADJUSTMENT
After leveling and joining the merchandisers,
adjust and level doors according to manufacturer’s
instructions shipped with each product. Factory
settings are lost due to vibration during shipment.
JOINING
Sectional construction means that two or more
merchandisers may be joined in line yielding one
long continuous display requiring only one pair
of ends. Joining kits and instructions are
shipped with each merchandiser.
To join like fixtures, a joining kit is required.
To join unlike fixtures, or like fixtures operating
at different temperatures, a 11/2inch (38 mm)
partition kit is required. To join same
temperature fixtures on different defrost cycles,
a plexiglass partition kit is required.
ALL JOINTS MUST BE AIR-TIGHT TO PREVENT
FORMATION OF ICE OR CONDENSATION.
Refer to separate joining instruction shipped
with each case
INSTALLING SPLASHGUARDBRACKETS
1. Attach splashguard retainer and splashguard
retainer support to splashguard support brack-
et using two screws per bracket.
2. INSTALL SPLASHGUARD SUPPORT BRACKETS
BEFORE PIPING CASE.The leveling brackets
have a maximum extension of one (1) inch
(25 mm) for uneven floors.
DO NOT PLACE SHIMS UNDER SPLASHGUARD
BRACKETS.
1-4 INSTALLATION
P/N 0387183_D WWW.HUSSMANN.COM
Splashguard Retainer
Splashguard
Retainer Support
Splashguard
Support Bracket
Screw
Base Rail
Screw
Bumper Retainer