LEVELING
Merchandisers must be installed level
to ensure proper operation of the
refrigeration system and to ensure
proper drainage of defrost water.
When leveling merchandisers, use a
carpenter’s level as shown.
Metal leveling shims or wedges are
provided with each merchandiser for
use if needed.
NOTE: BEGIN LINEUP LEVELING
FROM THE HIGHEST POINT OF THE
STORE FLOOR.
Place shims under the rail and make
sure that they are positioned at a base
component (crossbar). This transfers
the weight directly from the loaded
case through to the floor. Placing shims
at other locations will cause uneven
distribution of weight leading to piping
leaks, as well as sagging or wracked
doors.
Reach-In
P/N 0387183_D 1-3
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
5-Door Island Shown
Bottom Front
Support
Skid/External Base
Electrical Wireway
Electrical Wireway
Shim
Here NO SHIM
HERE
Base Component
Shim Here Shim Here
Rear of Reach-in
Approximately
Centered
Base
Component